AMF900 Series is a flange type electromagnetic flowmeter ideal for conductive liquids. It comes in sizes from 6 to 2000mm. AMF900 is widely used for tap-water, waste water, food & beverage pulp &paper and many other industrial fluid. AMF900 Series electromagnetic flowmeter could be used in compact or separate model with AMC Series converter of electromagnetic flowmeter.
 
FEATURES
  • Various liner and electrode satisfy most industrial applications
  • Flow Velocity range: 0-12 m/s, precise in low flow applications 
  • It comes any flanges such as, ANSI, DIN, JIS… etc
  • Excellent for high pressure application
  • Protection class: IP68 available; sensor submersible
  • FEP Liner is suitable for vacuum tube
  • High accuracy of +/-0.4% value of reading (or +/-0.2% value of reading)
  • With Forward/Reverse flowrate measurement function

Spesification Product :

Size: Electrode & Grounding:
6,10,15,20, 25,32,40,50,65,80,100,125 Stainless Steel 316L
150,200,250,300,350,400,450,500,600 Hastelloy B
700,800,900,1000,1200,1400,1600 Hastelloy C
1800,2000 mm Titanium
Measuring Range: Tantalum
Velocity   0 – 0.25 m/s min. Platinum
                0 – 12  m/s max. Tungsten Carbide
Material: Cable Entry:
Measuring Tube Standard :PG11  Option:1/2″NPTF
Stainless Steel 304 Ambient Temperature:
Flange
-25 to +60 oC
Carbon Steel (Standard) Process Connection:
Stainless Steel 304 (Option) Flange 
Stainless Steel 316, 316L (Option) Flange Type:
Coil Housing JIS 10K / JIS 20K / JIS 40K
Carbon Steel (Standard) ANSI 150# / ANSI 300# / ANSI 600#
Stainless Steel 304 (Option) DIN PN 10 / PN 16 / PN25 / PN 40
Stainless Steel 316,316L (Option) Grounding Resistance:
Liner: Must be  less than 10 
Polyurethane (25-600 mm) Accuracy:
Neoprene (50-2000 mm) +/-0.4% read-out values (Velocity >=0.5 m/s)
FEP (6-300 mm) +/-0.0025 m/s (Velocity < 0.5 m/s)
PTFE (25-800 mm) +/-0.2% read-out values
PFA (6-300 mm) (Suitable for AMC3100 converter only)
Protection Class: Temperature:
Junction box IP67, Body IP68
-10 ~ +60oC (Polyurethane, PU)
IP 68 (Submersible)
-20 ~ +70oC (Neoprene)
Conductivity:
-40 ~ +180oC (FEP)
More than 5 uS/cm
-40 ~ +180oC (PTFE/PFA)
Explosion Proof: Max. Pressure:
Exd(ib)ibqIIBT5 (with AMC3100/AMC4000 only) 350 Kg/cm2

 