ITRON AQUADIS DN25 FLOWMETER Rotary Piston Volumetric Type Water Meter. Aquadis Is An MID 2004/22/EC Approved Piston Type Water Meter For Residential And Commercial And Industrial Billing Applications
The Technology
Aquadis Combines The Advantages Of Piston Type Technology Together With Proven Reliabilityof The Extra Dry Register. No Gear Is In Contact With Water
The High Technology Implemented To Manufacture Measuring Chamber Ensures Stable And Durable Accuracy Of Aquadis Meter.
Metrological Performances
- Very Low Starting Flow Allows Leakage Detection
- Large Measuring Range
Robustness :
- Robust Hermetically Sealed IP68 Register TVM (Copper Can/Mineral Glass Enclosure) To Face All Field Situations, DN 20/25/30 In Option And DN 40/60/65 In Standard
- Plastic Register TSN Equipped With Wiper To Ensure Readabity In Tough Humid Conditions (Stadard For DN 20/25/30)
- Maximum Admissible Working Pressure In 16 Bar
Easy Reading
- Rotations Close To 360 Degree On Site
- Large Numbered Rollers With Good Contrast For Excellent Reading Capability
Communication Device
Pre-Equipped For Future Communication Through Cyble.
Working Principle :
The Aquadis Has Two Main Components : The Hydraulics That Allows Measurement Of The Water And The Register That Displays The Measured Water Volume
Transmission Interface Between Those Components Is Achieved By A Strong Magnetic Coupling :
- Aquadis Is A Piston Type Volumetric Meter
- Each Rotation Of The Piston In The Measuring Chamber Rpresents A Given Volume Of Water Passing Through, With Extra-Dry Registers
- Gears Are Protected By Water And Air Proof Enclosure
Communication :
The Aquadis Is Supplied Pre-Equipped With Cyble Target
Allows Communication And Remote Reading Through :
- Pulse Output (Cyble Sensor)
- M-Bus Protocol (Cyble M-Bus)
- Radio Frequency Wireless Link (Cyble RF)
Key Advantages Of Cyble Technlogy
- No Need For Additional On Th Meter To Implement Remote Reading
- Itron Standardized Meter Interface, Irrespective Of Meter Technology And Widely Spread On Itron Water Meters Range
- Reliability Bhrought By Electronic Switch (No Wear Or Bouncing)
- Reverse Flow Management
- Principle Proven On The Field With A 20 Years Experience
- Pre-Equipped Being Immune To Magnetic Tampering
Metrological Characteristics Itron Aquadis DN25 Flowmeter:
- Nominal Diameter (DN) : 25 Mm (1 Inches)
- Dynamic Range MID (R) – All Positions : 80-100
- Permanent Flow Rate (Q3) : 4 M³/H
- Standard Ratio Q3/Q1 : 80 M³/H
- Minimum Flow Rate (Q1) : 50 L/H
- Transitional Flow Rate (Q2) : 80 L/H
- Overload Flow Rate (Q4) : 5.0 M³/H
- Pressure Loss At (Q3) : <0.4 Bar
- Pressure Loss At (Q4) : <1 Bar
- Maximum Admissible Pressure (MAP) : 16 Bar
- Maximum Admissible Temperature : +0,1….+30 °C
- Operating Temperature : +5….+55 °C