PT. SRIAYU MULTI KREASI

Address : Jln. Hayam Wuruk

Gedung Harco Glodok Lantai 5 Blok A No. 42

Jakarta Barat

Pressure Gauge WIKA Model 711.12


DESCRIPTION

The differential gage is based on two independedtly operating Bourdon tube measuring system. The instrumet is therefore able to show the pressure from two measuring points and the resulting differential pressure on one display.

Differential pressure display

The standard version is designed with two pointers and a gauge pressure scale. The pointer for the minus connection is connected to an additional moving dial. On the scale of the moving dial, the differential pressure (± 50 % of the main scale’s full scale value) can be read directly.

Alternatively, in the version without additional moving dial, the differential pressure is not indicated

In the version with a subtracting movement, the differential pressure is indicated with only one pointer (the individual pressures of plus and minus connection are not displayed). The varience of scale versions ensures an optimal readability of all operating parameters.

The models 731.12 and 733.02, with wetted parts from stainless steel, have been specifically designed for the requirements in the process industry.

For harsh operating conditions, the instruments are also availabe with an optional liquid filling.

APPLICATIONS

  • Heating, ventilation and air-conditioning
  • For gaseous and liquid media that are not highly viscous or crystallising
  • Models 731.12 and 733.02 also for aggressive media
  • Models 713.12 and 733.02 with liquid-filled case are suitable for high dynamic pressure loads and vibrations

SPECIAL FEATURES

  • Scale ranges from 0…0.6 bar to 0…1,000 bar
  • Two process connections and two independent pointers
  • Differential pressure display with moving dial
  • Cost-effective and reliable

STANDARD VERSION

Version

Two independent measuring systems, process connections in line

Nominal size in mm

100, 160

Accuracy class

1.6

Scale ranges

0 … 0.6 to 0 … 1,000 bar

Scale range must be selected in relation to the maximum total pressure applied!

In heating systems with circulating pumps, the total pressureapplied is usually defined

as equal to the hydrostatic pressure plus the pump pressure.

In order to ensure a good readability, the differential pressure should not drop below

1/6 of the full scale value.

Pressure limitation

Steady: Full scale value

Fluctuating: 0.9 x full scale value

Short time: 1.3 x full scale value

Permissible temperature

Ambient: -20 … +60 °C

Medium: Model 711.12:

+60 °C maximum (soft soldered)

+100 °C maximum (brazed)

Model 731.12: +200 °C maximum

Temperature effect

When the temperature of the measuring system deviates from the reference

temperature (+20 °C): max. ±0.4 %/10 K of full scale value

Pressure elements

Model 711.12:

< 100 bar: Copper alloy, C-type, soft soldered

≥ 100 bar: Stainless steel, helical type, brazed

Model 731.12:

Stainless steel, all pressure ranges, welded