PT. SRIAYU MULTI KREASI

Address : Jln. Hayam Wuruk

Gedung Harco Glodok Lantai 5 Blok A No. 42

Jakarta Barat

Flow Meter Oval 3 Inch


General :

High accuracy positive displacement flowmeter for wide range of fluids including water, petroleum, solvent. The mechanical counter allows checking of total flowrates in the field. Output furnished flowmeter is also available optional.

Features :

  • High accuracy: ±0.5% RD (Option: ±0.2% RD)
  • Metering chamber is of a pocketless configuration and is applicable to a wide range of liquids including chemical liquids
  • Low pressure loss, high durability

Spesification Product :

Model : Single case type

Nominal size : 80 to 200mm

Transmission system : 7

Connection standard (Flange) : JIS 10, 20K, ASME/JPI 150

Flow range : 4 to 450m3/h (5types)

Operating temp. range : –10 to +120°C

Max. operating pressure  : 1.96MPa (Depends on connection standard.)

Accuracy : Within ±0.5% or ±0.2% of reading

Power supply : Not necessary (Power supply is required for output available model.)

Output : Pulse (Option)

Configuration : Explosionproof and also output type is available.

Applicable fluids : Water, gasoline, light oil, heavy oil, etc.

 

Major Specification :

Model Single case type Double case (inner and outer cases) type
Nominal size 80 to 200mm 250 to 300mm 25mm 40,50mm 50 to 200mm
Transmission system 7 4 2 4
Connection standard (Flange) JIS 10, 20K JIS 10, 16, 20, 30K JIS 30K JIS 10, 16, 20, 30, 40, 63K
ASME/JPI 150 ASME/JPI 150, 300 ASME 300 ASME/JPI 150, 300, 600
Flow range * 4 to 450m3/h 30 to 1000m3/h 0.08 to 4m3/h 0.26 to 40m3/h 2 to 450m3/h
(5types) (2types) (2types) (3types) (6types)
Operating temp. range –10 to +120°C –5 to +120°C –5 to +120°C –5 to +120°C
or
+120 to +200°C
Max. operating pressure 1.96MPa 4.59MPa 4.51MPa 9.51MPa
(Depends on connection standard.) (Depends on connection standard.) (120°C以下) (Depends on connection standard.)
Accuracy Within ±0.5% or ±0.2% of reading
Power supply Not necessary (Power supply is required for output available model.)
Output Pulse (Option)
Configuration Explosionproof and also output type is available.
Applicable fluids Water, gasoline, light oil, heavy oil, etc.

Major specifications (With jacket)

Model Jacketed single case type
Nominal size 25, 40, 50mm 100, 150, 200mm
Transmission system 7
Connection standard (Flange) JIS 10K, ASME 150
Flow range * 0.15 to 38m3/h 30 to 1000m3/h
(5types) (2types)
Operating temp. range –5 to +120°Cor+120 to +200°C
Max. operating pressure 1.18 MPa (220°C max.)
Accuracy Within ±0.5% of reading
Power supply Not necessary (Power supply is required for output furnished model.)
Output Pulse (Option)
Configuration Explosionproof and also output type is available.
Applicable fluids Water, gasoline, light oil, heavy oil, etc.

Have any Question or Comment?