Coriolis Mass Flow Meter ALIA ACS6000 Series


DETAIL PRODUCT
ACF6000 Series uses the Coriolis effect as a technique for liquid mass flow measurement. The ACF6000 can measure most of the liquids; the infrared light sensor makes it easy for you to set parameters & change the display data. The Double-C tube & Double-D Tube make it possible for the meter to be used in most liquid applications.
 
FEATURES
  • Can be programmed by infrared light sensor without opening cover
  • High turndown ratio of flow rate
  • It comes any flanges such as ANSI, DIN, JIS… etc
  • Excellent for high pressure application
  • Simple for installation, commission and maintenance
  • Self-diagnostic capabilities, cable faults, pipe vibration
  • High accuracy of +/-0.2% of reading (or +/-0.1% of reading)
  • With forward / reverse flow rate measurement function

Spesification Product :

Sensor Type: Display:
C tube (10-40mm) / U tube (50-150mm) 2 lines LCD with illumination
Size: Flow Rate Unit
10mm ~ 200 mm (3/8″ ~ 8″) g/s, Kg/min, kg/Hr, T/Hr, 5 Digit
Flow Range: Density Unit
0 – 1000 Kg/Hr ~ 0 – 1106000 Kg/Hr Kg/m3, g/cc, 5 Digit
Accuracy: Totalizer Unit
+/-0.2% +/-ZS of reading (Standard) g, Kg, Ton, L, M3, 11 Digits
+/-0.1% +/-ZS of reading (Optional) Temperature
Repeatability: oC,  oF, 4 Digits
+/-0.03% +/-ZS of reading Keypad:
Density Range: 3 keys from Internal setting + Infrared light 
200 – 2300 Kg/M3 (0.2 – 2.3 g/cm3) Sensor, can be programmed without
Accuracy Opening the cover
+/-0.002 g/cm3 Turndown Ratio:
Temperature Range: 20  : 1
-40 oC ~ +125 oC (Standard) Damping:
-40 oC ~ +250 oC (Optional, Separate Only) 0.01 To 1.0 Seconds
Material: Low Flow Cutoff:
Wetted Parts 0.0% ~ 9.0%
Stainless Steel 316L Communication:
Flange RS485 (Modbus Protocol)
Stainless Steel 316L Hart Signal (Optional)
Sensor Housing Current Output:
Stainless Steel 304 4-20 mA (Isolated)
Junction Box Load
Aluminum Alloy (Epoxy Paint) Max. 750 
Process Connection: Output Unit
Flange  Mass / Volume / Density / Temperature
Flange Type: Pulse (Alarm) Output:
JIS 10K / JIS 20K / JIS 40K Open Collector
ANSI 150# / ANSI 300# / ANSI 600# Rating
DIN PN 10 / PN 16 / PN25 / PN 40 3-30Vdc, 50mA Max.
Protection Class: Power Supply:
IP 67 90-260 VAC, 50/60 Hz  or 24 VDC +/-10%
Explosion Proof Exde (ib) IIC T6 (Optional) Power Consumption:
Installation: 30 – 40 W (Depend on sensor size)
Compact or Separate Cable Entry:
Signal Cable Length: Sensor to Converter- 3/4″ G
10M – 100M Signal output / Power supply- M20
Ambient Temperature:
-40 oC to +60 oC
Max. Pressure:
63 Kg/cm2

 