Features
- Sturdy stainless steel measuring cone
- Operating pressure up to 44,100 psi
- Process temperatures from -328 to 752°F
- Flow rates for liquids:
- Lower limit: 0.47 gph
- Upper limit: 26,418 gph
- Flow rates for gases:
- Lower limit: 0.002 scfm
- Upper limit: 1736 scfm
- Measuring range: 10:1
- Accuracy: ±1.6 %
- High application security, even with extremely small flows
- Excellent long-term stability
- Wide range of flange, threaded, clamp process connections
- Resistant to extreme chemical, mechanical and thermal loads
- All components replaceable
- Heating jacket available for the measuring section
Krohne M9 Indicator
- Simple, low-cost installation: Measure and display without auxiliary power supply
- Large scale for good readability
- 2 limit switches (NAMUR or 3-wire transistor)
- 2-wire analog output 4 to 20mA with HART – Profibus PA interface
- 6-digit flow counter with pulse output (non Ex)
- Optional stainless steel housing for corrosive atmospheres
- ATEX, FM, CSA approvals for use in hazardous areas; SIL 2 certified
Krohne M10 Indicator
- Digital indicator with I/O
- 2 limit switches (NAMUR or 3-wire transistor)
- 2-wire analog output 4 to 20mA with HART
- 12-digit flow counter with pulse output and reset input
- Pressure resistant, enclosed housing
- ATEX, FM, CSA approvals for use in hazardous areas